LAPARA Double-conversion uninterruptible power supply with display LA-ON-10K-LCD-V.10 10KVA 10KW DSP0000044210

Price: €1,710.60
Tax included
Share
DeliveryOrder within the next — to receive it approximately Wednesday 25

Estimated delivery between Wednesday 25 and Thursday 26

Ships from Tudela

Fechas estimadas para España peninsular; se ajustarán con tu código postal y forma de entrega.

IVA intracomunitario

La exención intracomunitaria puede aplicarse a una entrega a otro Estado miembro si el NIF-IVA es válido y el destino cumple los requisitos. La comprobación por sí sola no determina el tratamiento fiscal.

Cómo se comprueba el IVA
¿Eres profesional del sector?

Puedes solicitar una cuenta profesional e indicar los datos de tu actividad. La solicitud queda pendiente de revisión; puedes consultar su estado en tu cuenta.

Más información sobre cuentas profesionales
Canarias, Ceuta y Melilla sin IVA español

El tratamiento depende del destino de entrega y de la coherencia de la dirección. Pueden corresponder IGIC, IPSI, aranceles u otros cargos locales.

Más información sobre destinos e impuestos
Features of the Lapara Online 10 kVA / 10 kW LCD Terminal Block UPS
The Lapara Online LA-ON-LCD-6-10K-LCD-V.10 10000 VA / 10000 W UPS is designed to protect critical equipment and installations that require a continuous, stable power supply. Thanks to its true online double-conversion technology, DSP control and output power factor of 1, it provides high-quality power for servers, IT systems, communications infrastructure and professional applications. It features an LCD, efficiency above 94%, advanced management and compatibility with N+X parallel redundancy configurations.
Online double-conversion technology and power factor 10000 W
Its online double-conversion system keeps connected equipment protected against power grid disturbances, providing a pure sine wave output and eliminating transfer times between the mains and the battery. The output power factor of 1 allows the full rated capacity of the UPS to be used, while DSP digital processing helps maintain a precise and stable power supply.

Rated power : 10000 VA / 10000 W.
Technology: true online double conversion with DSP control.
Output power factor: 1.
Waveform: pure sine wave in battery mode.
Mains/battery transfer time: 0 ms.
Inverter/bypass transfer time: 0 ms.
Inverter/ECO transfer time: less than 10 ms.
Redundancy: compatible with N+X parallel configurations.

Wide-range, high-stability electrical input
The wide input voltage range allows the UPS to adapt to different power supply conditions, reducing the need to use the batteries in response to certain voltage fluctuations. Its input power factor of 0.99 or higher and low harmonic distortion contribute to efficient energy use.

Input voltage nominal : 208/220/230/240 V AC.
Voltage range at 50% load : 110-300 V AC ± 3%.
Voltage range at 100% load : 176-300 V AC ± 3%.
Input frequency: 46-54 Hz or 56-64 Hz.
Frequency range at 50 Hz: 46-54 Hz.
Frequency range at 60 Hz: 56-64 Hz.
Input connection: single-phase with earth (phase + neutral).
Input power factor: greater than or equal to 0.99 at nominal voltage and 100% load.
Current harmonic distortion (THDi): less than 4% at 100% load and less than 6% at 50% load.

Configurable output with precise voltage regulation
The programmable output voltage allows the UPS operation to be adapted to the requirements of different professional installations. In battery mode, it maintains 1% voltage regulation and a stable frequency, providing a suitable power supply for sensitive electronic equipment. In addition, its low harmonic distortion improves output signal quality.

Output voltage: programmable to 208/220/230/240 V AC.
Voltage regulation in battery mode: 1%.
Programmable synchronised frequency: 46-54 Hz at 50 Hz / 56-64 Hz at 60 Hz.
Frequency in battery mode: 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz, programmable.
Crest factor: 3:1 maximum.
Harmonic distortion with linear loads: less than or equal to 1% THD at 100% load.
Harmonic distortion with non-linear loads: less than or equal to 4% THD at 100% load.

Overload protection and continuous operation
The Lapara 10 kW UPS incorporates protection mechanisms against overload conditions, with different tolerance times depending on whether it is operating on mains power or batteries. This capability allows it to manage temporary increases in electrical demand and protect the system under abnormal operating conditions.

Overload in AC mode from 100% to 110%: 10 minutes.
Overload in AC mode from 110% to 130%: 1 minute.
Overload in AC mode above 130%: 1 second.
Overload in battery mode from 100% to 110%: 30 seconds.
Overload in battery mode from 110% to 130%: 10 seconds.
Overload in battery mode above 130%: 1 second.

High energy efficiency and battery management
Thanks to an efficiency of over 94% in AC mode, this UPS reduces energy losses during normal operation. It incorporates 20 batteries rated at 12 V and 9 Ah and has a charging system with a maximum current of 4 A, suitable for maintaining the unit’s energy reserve and supplying power when the mains supply is interrupted.

Efficiency in AC mode: greater than 94%.
Efficiency in battery mode: greater than 91%.
Battery type: 12 V / 9 Ah.
Number of batteries: 20 units.
Maximum charging current : 4 A ± 10%.
Charging voltage: number of batteries x 13,65 V ± 1%.
Load regulation: ajustable.

LCD display and audible alarm system
The integrated LCD display makes it easy to monitor the UPS status and the main electrical parameters without additional equipment. It allows you to check the connected load, battery level and operating conditions. It also features distinct audible alarms to quickly identify low battery, overload or fault conditions.

Display information: UPS status, load level and battery level.
Electrical parameters: input and output voltage.
Additional information: discharge time and fault conditions.
Alarm in battery mode: audible alert every 4 seconds.
Low battery alarm: audible alert every second.
Overload alarm: two audible alerts per second.
Fault alarm: continuous sound.

Professional communications and remote management
The Lapara Online 10000 VA UPS incorporates Smart RS-232 and USB communication interfaces to facilitate monitoring from different operating systems. It also supports optional SNMP management, which allows the power supply to be controlled and monitored via an SNMP manager or web browser, a particularly useful feature in business environments and IT infrastructures.

Communication interfaces: Smart RS-232 and USB.
Windows compatibility: Windows 2000, 2003, XP, Vista, 2008, 7, 8 and 10.
Other compatible systems: Linux, Unix and Mac.
SNMP Management: opcional.
Remote monitoring: via an SNMP manager and web browser with the corresponding SNMP option.

Design for professional installations and operating conditions
With a professional installation format and terminal block connection, this UPS is designed for environments requiring a high-power power supply infrastructure. Its dimensions and environmental characteristics allow its location to be planned, taking into account the ventilation, temperature and humidity conditions required for proper operation.

Connection type: terminal block (connection terminals).
Dimensions (depth x width x height): 592 x 250 x 576 mm.
Net weight: 83 kg.
Operating temperature: from 0 to 40 °C.
Recommended temperature to preserve battery life: avoid temperatures above 25 °C, as they may reduce its service life.
Relative humidity: 20% to 95%, non-condensing.
Operating altitude: below 1000 m.
Noise level: below 58 dB at 1 metre.
Brand
LAPARA
Reference
DSP0000044210
EAN-13
8436597250672
Weight
100 kg

Comments (0)